Complete system solutions that meet your specific requirements

Guldager produce and deliver tailor-made installations for the process industry. We design the water for the purpose you need. Whether it is for maintenance of machinery and installations in production or you have special requirements for the water involved in the production, calcium or salts in the water do not affect the final product.

Water for breweries and food industry must meet requirements for hardness, purity and much more. And the production equipment must be protected against rust and calcification so that it lasts as long as possible.

In power plants and district heating systems, food and process water can also often be kept under control in terms of the content of corrosive substances, salts and minerals.

In cooling systems water treatment is used to protect against corrosion, bacteria and fouling. Based on our many years of experience in water treatment, we have developed CatoCool, a unique concept for the treatment of cooling water systems. CatoCool is a natural alternative to a chemical-based solution.

We have the technology to deliver water with exactly the properties needed.

procesindustri-vandbehandling

Contact us at +45 48 13 44 00 and let’s have a professional and non-binding chat about your needs.

Hydrus-til-procesindustrien

CASE: Completely clean water with significant savings

In the food industry there are high demands on the process water quality. In a larger slaughterhouse in Jutland, Guldager installed a number of ”UniSoft® Hydrus” softener installations to ensure clean process water without calcium.

The soft water is essential for optimal cleaning in the slaughtering process with minimum consumption. At the same time there is no deposition of calcium on tiles and equipment, which makes the cleaning easier.

The water consumption for rinsing at the slaughterhouse was high, and it was therefore crucial that the installation could reduce the consumption of salt and water for regeneration compared to traditional softening installations.

Are you experiencing any of these problems?

If the answer is yes, it is time to examine the water quality in the property. Contact us or read more about our products below.

Do you have any problems with sludge deposits in your cooling plant?

Problem:

Partikler fra luften vaskes ud i køletårnet

Solution:

Filtration

These products can solve it:

UniFilter, sand filters

Is your water consumption for draining from the cooling tower too high?

Problem:

High evaporation of cooling water

Solution:

Recycling of drainage water up to 75%

These products can solve it:

CatoRec

Corrosion of hot water pipes and hot water boilers?

Problem:

Corrosion in water pipes/boilers

Solution:

Katolysis/Electrolysis

These products can solve it:

UniCat®, Cathodic protection

Lime coatings in hot water pipes and boilers

Problem:

Calcium in the water

Solution:

Softening of the hot water

These products can solve it:

UniSoft® 30-60-90 / UniSoft® Hydrus

Red water or mucus in the water

Problem:

Corrosion, lime and bacteria

Solution:

Catalysis/Electrolysis, softening, bacterial prevention

These products can solve it:

UniSoft® 30-60-90 / UniSoft® Hydrus, Unicat®, UniControl, LegioControl®, Healthy water concept

High maintenance costs eg for pumps and valves

Problem:

Lime in the water

Solution:

Softening

These products can solve it:

UniSoft® 30-60-90, UniSoft® Hydrus

High cost of return heat

Problem:

Poor heat transfer due to lime

Solution:

Softening

These products can solve it:

UniSoft® 30-60-90, UniSoft® Hydrus, CalcFree

Lime coatings on work surfaces

Problem:

Lime in the water

Solution:

Softening

These products can solve it:

UniSoft® 30-60-90, UniSoft® Hydrus

Delta-p

softliQ MC32

softliQ SC18 & SC23

UniSoft® Hydrus

Driftsøkonomisk, mængdestyret blødgøringsanlæg til det store forbrug. Fra 20 m³/t.

FAQ – to the most common questions

Is corrosion protection needed today?

Yes, although most installations today are made of corrosion-resistant materials, it is still necessary to protect steel containers, sand filters, etc. In addition, tens of thousands of installations are made of galvanized steel with many years on the bag, which can last for as many years as possible with active corrosion protection.

When the hot water boiler is removed, we do not need corrosion protection?

Well, keep in mind that the piping system still needs to be protected against corrosion (Unicat).

How can softening improve the operation costs?

By avoiding lime deposits on heaters and in pumps and valves, the cost of maintenance is reduced.

Is it necessary to disinfect the boiler every year?

Yes, an annual cleaning of the boiler combined with disinfectant with chlorine dioxide is recommended as the best way to prevent Legionella.

Does corrosion protection not remove lime?

No, it only prevents corrosion, but the lime can be removed with a softening installation.

If you did not find an answer to your question, please call us +45 48 13 44 00